Test Code ACRMA Acetylcholine Modulating Antibody
Additional Codes
99521
Methodology
Semi-Quantitative Flow Cytometry
CPT
86043
Specimen Type
Blood
Preferred Collection Container
SST
Collection Volume
1.0 mL
Minimum Collection Volume
0.6 mL
Collection Instructions
Separate from cells ASAP or within 2 hours of collection.
Transport
Refrigerated
Rejection Criteria
Contaminated, hemolyzed, or severely lipemic specimens.
Specimen Storage and Stability
Ambient: 48 hours; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles)
Turn Around Time
3-8 days
Lab Department
Referred Testing
EPIC Code
LAB837
Acceptable Collection Container
R-NoGel
Testing Volume
0.3 mL
Patient Preparation
None
Day(s) and Time(s) Performed
Sunday through Friday
STAT Availability
No
LOINC
30192-9
Alias
AChR Antibody; ACHR modulating antibody; Muscle nicotinic Acetylcholine Receptor (AChR) Modulating Antibody; Myasthenia Gravis Antibodies