Test Code ALUMIN Aluminum, Serum
Additional Codes
99266
Methodology
Quantitative Inductively Coupled Plasma-Mass Spectrometry
CPT
82108
Specimen Type
Blood
Preferred Collection Container
NavyRed (Serum)
Collection Volume
4.0 mL
Minimum Collection Volume
1.0 mL
Collection Instructions
Separate from cells ASAP or within 2 hours of collection. Transfer 2 mL serum to an ARUP Trace Element-Free Transport Tube (Metal Free)
Transport
Ambient
Rejection Criteria
pecimens that are not separated from the red cells or clot within 2 hours. Specimens collected in containers other than specified. Specimens transported in containers other than specified.
Specimen Storage and Stability
Ambient: Indefinitely; Refrigerated: Indefinitely; Frozen: Indefinitely (If the specimen is drawn and stored in the appropriate container, the trace element values do not change with time.)
Turn Around Time
2-5 days
Lab Department
Referred Testing
EPIC Code
LAB665
Acceptable Collection Container
NavyRed (Serum no additive)
Testing Volume
0.5 mL
Patient Preparation
Diet, medication, and nutritional supplements may introduce interfering substances. Patient should be encouraged to discontinue nutritional supplements, vitamins, minerals, and non-essential over-the-counter medications (upon the advice of their physician).
Day(s) and Time(s) Performed
Tuesday, Thursdy, Saturday
STAT Availability
No
LOINC
5574-9
Alias
Al; Al, Serum; Aluminium; Aluminum; Aluminum, serum