Test Code ROMP Rupture of Fetal Membrane, ROM+
Methodology
Immunochromatographic
CPT
84112
Specimen Type
Vaginal mucosal swab
Preferred Collection Container
ROMCollection Instructions
Clinician Collected. See ROM+ Collection Instructions on the left side under Patient Collection Information. Insert the sterile swab tip into the vagina 2-3 inches (5-7 cm). Withdraw the swab after a minimum of 15 seconds. Place swab in buffer vial and mix for 15 seconds. Bend and break swab, leaving the swab in the buffer solution. Ensure swab stick is short enough so that the flat screw top lid can be securely fastened. Send to lab.Transport
Ambient
Rejection Criteria
Grossly bloody; Improperly labeled; leaking specimens
Specimen Storage and Stability
6 hours in buffered solution
Lab Department
Chemistry
Alias
Rupture of Membranes, Premature ROM, PROM, Fetal Membrane Rupture PP12/AFP
EPIC Code
LAB7887A
Acceptable Collection Container
ROM+ Collection Kit
Day(s) and Time(s) Performed
24 hours, 7 days/week
LOINC
69945-4