Test Code ROMP Rupture of Fetal Membrane, ROM+
Specimen Type
Vaginal mucosal swab
Preferred Collection Container
ROMAcceptable Collection Container
ROM+ Collection Kit
Collection Instructions
Clinician Collected. See ROM+ Collection Instructions on the left side under Patient Collection Information. Insert the sterile swab tip into the vagina 2-3 inches (5-7 cm). Withdraw the swab after a minimum of 15 seconds. Place swab in buffer vial and mix for 15 seconds. Bend and break swab, leaving the swab in the buffer solution. Ensure swab stick is short enough so that the flat screw top lid can be securely fastened. Send to lab.Rejection Criteria
Grossly bloody; Improperly labeled; leaking specimens
Specimen Storage and Stability
6 hours in buffered solution
Day(s) and Time(s) Performed
24 hours, 7 days/week
EPIC Code
LAB7887A
Transport
Ambient
Lab Department
Chemistry
CPT
84112
Methodology
Immunochromatographic
Alias
Rupture of Membranes, Premature ROM, PROM, Fetal Membrane Rupture PP12/AFP
LOINC
69945-4