Test Code RSVA RSV Antigen Test
Methodology
Chromatographic immunoassay
Specimen Type
Nasopharyngeal washes or aspirates, NP swab in M4RT or Eswab Blue (Mini-tip) Cap
Collection Volume
3-5 mL
Minimum Collection Volume
1 mL
Collection Instructions
Specimens must be properly labelled with the patient’s name, specimen type, hospital identification number if known, time and date of collection, and initials of person collecting specimen.
Rejection Criteria
Insufficient volume of specimen; specimen >72 hours old; Specimens that have not been refrigerated; Incomplete requisition; Unlabelled specimen
Specimen Storage and Stability
Transport immediately to North Campus Laboratry. Specimen should be refrigerated if there is any delay in transit to the laboratory. Specimen is stable 72 hours at 2-8 C.
Turn Around Time
Stat – 1 hour
Lab Department
Microbiology
Alias
RSV Antigen Test; RSV Antigen Detection; RSV; Respiratory Syncytial Virus (RSV) Detection;
EPIC Code
LAB6180
Acceptable Collection Container
Sterile container for washes or aspirates. M4RT transport media for swabs.
Additional Information
Nasal washing in sterile container.
Nasopharyngeal Swab is also an acceptable specimen. Polyester, rayon, foam and cotton nasopharyngeal swabs are acceptable. Add swab specimens to M4RT transport media within one hour of collection.
Day(s) and Time(s) Performed
Monday through Sunday, 24 hours