Sign in →

Test Code RSVA RSV Antigen Test

Methodology

Chromatographic immunoassay

Specimen Type

Nasopharyngeal washes or aspirates, NP swab in M4RT or Eswab Blue (Mini-tip) Cap

Collection Volume

3-5 mL

Minimum Collection Volume

1 mL

Collection Instructions

Specimens must be properly labelled with the patient’s name, specimen type, hospital identification number if known, time and date of collection, and initials of person collecting specimen.

Rejection Criteria

Insufficient volume of specimen; specimen >72 hours old; Specimens that have not been refrigerated; Incomplete requisition; Unlabelled specimen

Specimen Storage and Stability

Transport immediately to North Campus Laboratry. Specimen should be refrigerated if there is any delay in transit to the laboratory. Specimen is stable 72 hours at 2-8 C.

Turn Around Time

Stat – 1 hour

Lab Department

Microbiology

Alias

RSV Antigen Test; RSV Antigen Detection; RSV; Respiratory Syncytial Virus (RSV) Detection;

EPIC Code

LAB6180

Acceptable Collection Container

Sterile container for washes or aspirates. M4RT transport media for swabs.

Additional Information

Nasal washing in sterile container.

Nasopharyngeal Swab is also an acceptable specimen. Polyester, rayon, foam and cotton nasopharyngeal swabs are acceptable. Add swab specimens to M4RT transport media within one hour of collection.

Day(s) and Time(s) Performed

Monday through Sunday, 24 hours